Abstract

The main aims of this project to alert the relay when some difference in supply power for shield electrical home equipment and industrial instrument under over-voltage and under-voltage. The chances of damaged electronic devices are more because the equipment is much conscious in different power supply. In this scenario, it needs an extra shield system to shield the instrument by a different power. With the voltage comparator integrated circuits decide the trip of relay system get function as the voltage differs higher than or down the set worth. The major profit by that it also shields the 3-phase device from 1-phase and variation of power in ac power waveform. In the coming days it also possible earth fault detection and protection.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Article Details

How to Cite
Prasad, D. P. K. ., Lingaiah, T., Kumar, D. K. K., & Naik, B. T. . (2019). DESIGNING OVERVOLTAGE AND UNDERVOLTAGE TRIPPING CIRCUIT FOR DISTRIBUTED SYSTEM LOAD WITH GSM ALERT USING MICROCONTROLLER. Turkish Journal of Computer and Mathematics Education (TURCOMAT), 10(2), 1963–1967. https://doi.org/10.61841/turcomat.v10i2.14566
Section
Research Articles

References

. J.B GUPTA (2018) A COURSE IN POWER SYSTEMS, PART-III: Switchgear and Protection, Chapter-9.

] ROBERT L. BOYLESTAD, LOUIS NASHELSKY (2015) Electronic Devices and Circuit Theory 11th Edition,

Chapter-10.

. “IEEE Recommended Practice for Monitoring Electric Power Quality,” IEEE Std. 1159-1995, June 1995.

. Girish Chandra Thakur, Kumar Shantanu Kaushal, Manish Ranjan, Sandip kumar Gupta. “Implementation of single

phasing, over voltage, under voltage, Protection of Three Phase Appliances without using Microcontroller” , Int. journal

of Engineering Research and Applications,ISSN:2248-9622, vol. 5, Issue 5, (Part-6), pp.110-115,May 2015.

. Sourav Ghosh, Soumik Bakshi, saurav Ghosh, Rahul kundu, Indrajit Koleys. “Development of a low cost under

voltage and over current protection device”, Int. Journal of Advance Research in Electrical, Electronics and

Instrumentation Engineering, ISSN: 2278-8875, vol.5, Issue 5, May 2016.